Tungsten Filament Lamps
Vacuum Lamps
The tungsten filament evaporates more rapidly as the temperature of the filament goes up. The evaporated tungsten particles tend to deposit on the glass envelope, causing over time, an increase in light absorption. Depending on the application, the light output obstruction could be high enough to end the useful life of the lamp. Eventually, the filament material will evaporate enough to cause the filament to break, completely ending the life of the lamp. Both of these effects are strongly dependent on the temperature of the filament, which is why long life vacuum lamps tend to be operated at the low end of the temperature range and the light has a yellowish appearance.
The electrical resistance of the tungsten filament at room temperature is initially quite low. When electrical power is first applied to the lamp, a large in-rush current causes rapid heating of the filament. The resistance of the filament rises to a value five to ten times the cold resistance, which causes the amount of current drawn by the lamp to stabilize and the lamp to emit a stable light output. Depending on the size of the filament, the in-rush period can be from tens of milliseconds to hundreds of milliseconds. This in-rush current requirement should be taken into account in the selection of the power source for a specific lamp application.
Gas-Filled Lamps
Gas-filled lamps require more power to achieve the same filament temperature than vacuum lamps. The surrounding gas cools the filament while suppressing evaporation, and reducing the migration of evaporated tungsten to the wall of the lamp. The higher operating temperature of gas-filled lamps produce more light output per watt of input power, which justifies their use in critical applications.
Tungsten Filament Lamps in the News
Halogen Lamps
The light output of a halogen light is more stable than a non-halogen gas lamp due to the cleaning action of the halogen gas on the lamp envelope. This feature coupled with the high color temperature of the light and long-life make these lamps very desirable for many industrial and scientific applications. The restriction on duty cycle due to the requirement to maintain the envelope of the lamp at sufficient temperature to initiate the halogen cycle is a disadvantage. However, in continuous duty applications it is relatively easy to provide correct ventilation to ensure the proper operating temperature.
Interested in buying Tungsten Filament Lamps?
- Visible-IR Lamps
- Tungsten filament lamps with reflectors for a high infrared output.
- Lens-end Lamps
- Small lamps with lenses attached to increase the light output. Often used for spot lighting applications.
Life at Design & Operating Voltages


Lamp life expressed in hours is calculated at design voltage and under ideal laboratory conditions. Deviation from design voltage will result in decreased or increased values of lamp life. This deviation will also alter values of current consumption, brightness, and color temperature. These deviations should be used advantageously by the design engineer to enhance the technical lamp's specifications for the specific application.
Figure 1 is supplied to express percent variations in current, color temperature, and brightness when operating voltage differs from design voltage.
Spectral Radiation Output

The spectral radiation of a lamp is a function of the temperature of the filament. The curves in figure 2 give the output versus wavelength over a typical range temperatures for lamps ranging from vacuum to gas-filled with halogen.
Want more information about...?
- Miniature Lamps
- Need a light source the size of an LED but with higher output? Miniature Lamp lighting from International Light Technologies.
- LED Modules
- Looking for LED module lighting? International Light Technologies offers LED modules to suit any application.
- LED Lighting
- High efficiency LED lighting from ILT. Available in many sizes and colors.
- Halogen Lamps
- Bright Halogen Lamps from ILT. Wide spectral output range; UV, Visible, and IR available.
- Illumaled Under Cabinet Lighting
- Sleek new LED under cabinet lighting from International Light Technologies. Thinner and more efficient than halogen with a 50,000 hour lifetime.
- Neon Lamps
- Standard and high brightness neon lamps from International Light Technologies. Several colors and sizes available.
- NDIR Gas Sensors
- Visible Infrared lamps from International Light Technologies are perfect for use with Infrared Gas Sensors. Several options of leads, life hours, and sizes.
More Information

Rated life as specified here is expressed in terms of hours. Rated life is calculated at design voltage, with alternating current, and under ideal laboratory conditions. In actual use, lifetime may be shortened as a result of hostile environments such as shock, vibration, and extreme temperatures. Life may be substantially increased, by selecting an operating voltage less than the design voltage. This decrease from design voltage will also result in a cooler filament providing increased resistance to shock and vibration.
Because of slight variations in miniature lamp manufacturing and in the component parts, it is impossible to have each individual lamp operate for exactly the life for which it was designed. Lamp life is rated as the average life of a large group of lamps. At the end of rated life approximately 50% of the lamps in a large group will have failed and 50% will continue to operate as detailed in Figure 3. Please note that this data pertains to all tungsten filament lamps: gas filled, halogen and vacuum.
Filament Shapes
Filament shapes used for lamps are classified into several different forms according to the filament sizes (filament diameter and length) and shock resistance. See figure 4.

Rapid Lamp Calculator Diagram
This diagram allows the user to determine the dependence of Current, Mean Spherical Candela and Life on the value of voltage applied to the lamp as a percentage of the design voltage for that lamp. Draw a horizontal line through the percent of design voltage tobe used and read the value of the calculated parameters on the right
side of the diagram.